Sampling Technique

Sampling technique by Fluid Sample Pump

Sampling Technique Figure Explanation

1

Sampling Fluid Pump -clear head with rigid stand.
More easy and convenient handling during drawing oil sample.
2 Apply to do gravimetric - patch test as field test on-site.
3 Sampling Fluid Pump -yellow head type
Good for starting tool for oil sampling
4

Figure 4-7

Drawing oil samples by Fluid Sample Pump .

A new tube should be used with the fluid pump every time a sample is taken for oil analysis.

5
6
7
8 Drawing oil sample from lube sumps and oil tanks.
9 Oil sampling of reservoirs or tanks by using rod to obtain oil samples at specific point.
10 Sampling from bottom of drum.

Sampling technique by Minimess valve and Probe

Sampling Technique Figure Explanation

11

Minimess valve
The preferred method for oil sampling
Quality and reliable sampling method
And be consistent method
12 Picture of Sampling Probe
13 Picture of Sampling Probe and Minimess Valve
14

Utilize Minimess Valve to obtain oil samples from engine at pressurized system location.

Figure 14 ,location is at Oil Filter Housing

15 Utilize Minimess Valve to obtain oil samples from points of forced lube circulating system.

Points of smapling will be Primary Point and Secondary Points.
16 Utilize Minimess Valve to obtain oil samples from return line.
17 A Minimess Valve installed on a hydraulic machinery.
18 Oil Reservoir Sampling.

In circulating oil reservoir , take sample as close to return as possible.
Tool : Tubing Sampling Valve 509

Sampling technique by combination of Sampling Fluid Pump and Minimess valve

Sampling Technique Figure Explanation

19

Utilize Minimess Valve and Pump to obtain oil samples from return line (non pressurized line).

20 Utilize Minimess Valve and Pump to obtain oil samples from drain port (low pressurized location).
21 Utilize Minimess Valve and Pump to obtain oil samples from oil resevoirs or tanks at dedicated point (non pressurized location).
22

Utilize Minimess Valve and Pump to obtain oil samples from filter housing.

 