"Approximately 90 percent of all bearings are lubricated with grease but how much do you know about the grease or greased bearings in your plant? Grease analysis is certainly not for every bearing, maybe it's not even for most bearings. But when you have a need to know, a thorough analysis of the grease in question can prevent headaches and save money. "
|
|
Bill Herguth, Herguth Laboratories |
FocusLab grease analysis will provide information grease coondition (serviceability) bearing condition and contamination |
Recommendation (Regular Routine Oil Analysis)
GreaseCheck™ 822 |
GreaseCheck™ 832 |
All Tests below are for GreaseCheck™ 822
Wear Metal Elements - condition
- RDE Fine Wear Metal -18 elements, ASTM D6595
- RFS Coarse Wear Metal -11 elements, ASTM D6595
- PQ Index
Oil Condition
- NLGI / Consistency Number FTM
- Dropping Point, ASTM D2265
- Oil Bleeding FTM
Contamination
- %Moisture & Water, ASTM D1744
- Deleterious Particles, ASTM D1404
- Wrong Grease / Mixing Grease, FTIR
|
- Report with interpretation
|
|
All Tests below are for GreaseCheck™ 832
Wear Metal Elements - condition
- RDE Fine Wear Metal -18 elements, ASTM D6595
- RFS Coarse Wear Metal -11 elements, ASTM D6595
- PQ Index
- Ferrographic Analysis, ASTM D7690M
Oil Condition
- NLGI / Consistency Number FTM
- Dropping Point, ASTM D2265
- Oil Bleeding FTM
Contamination
- %Moisture & Water, ASTM D1744
- Deleterious Particles, ASTM D1404
- Wrong Grease / Mixing Grease, FTIR
|
- Report with interpretation
|
|
Highlight Focuslab's unique testing in GreaseCheck™ 822
|
Highlight Focuslab's unique testing in GreaseCheck™ 832
|
Note: The above recommended test package will be guideline, the suitable test package may be vary depend upon right application, environment severity, critical factor, machine age, and so on.
Test Description
Sample Quantity: 5-10 grams
Reports
LubeCheck™ Oil Analysis Report provide :-
- Display an easy-to-read and understand.
- Information for wear condition ,lubricant condition and contamination.
- Interpretation and recommendation of the result . Option for Bilingual.
- Color coded display of overall condition for present sample and history condition of previous sample.
|
|
- Color coded problem highlights.
- Provide new oil or reference oil for comparing result and as baseline.
- Publish Alarm Limit range of the equipment and oil.
- Comprehensive trending graph of most parameters.
- LubeCheck™ Oil Analysis offers reporting options via internet, email and fax.
|
|
|
Turnaround Time Service
The report is typical available within 7 working days of sample receipt at FocusLab's labortory.
Examples of report
Remarks: Oil samples (after completion of testing) will be retained in our laboratory for approx 60 days ,just in case of in-depth testing and/or any future purpose. |
|
,,,,,,,,,,,,,,,,,,,,,,,,,,,,, |
Technical articles and case study related to this application
|
|
|
Deferral Programs
Danny Shorten , Lloyd’s Register |
|
|
|
|
|
Entertainment Engineering , Volume 3 Issue 9 |
|
|
|