Pump , Vacuum pump ,Fan ,Blower , Motor( gear and bearing lubrication) |
Recommendation (Regular Routine Oil Analysis)
PumpCheck™ 804 |
PumpCheck™ 894 |
All Tests below are for PumpCheck™ 804
Wear Metal Elements - condition
- RDE Fine Wear Metals-18 elements
- RFS Course Wear Metals-11 elements
Oil Properties & Condition
- Oil Condition ; oxidation, nitration
- Viscosity @ 100 °c
- TAN (Total Acid Number)
Contamination Condition
- Oil Contamination ; dirt & dust
- %Moisture & Water
- Wrong oil contamination*
|
- Report with interpretation
|
|
All Tests below are for PumpCheck™ 894
Wear Metal Elements - condition
- RDE Fine Wear Metals-18 elements
- RFS Course Wear Metals-11 elements
Oil Properties & Condition
- Oil Condition ; oxidation, nitration
- Viscosity @ 100 °c
- TAN (Total Acid Number)
Contamination Condition
|
- Report with interpretation
|
|
Highlight FocusLab's unique testing
in PumpCheck™ 804
|
Highlight FocusLab's unique testing
in PumpCheck™ 894
|
Note: The above recommended test package will be guideline, the suitable test package may be vary depend upon right application, environment severity, critical factor, machine age, and so on.
Application
Vacuum pump
All Tests below are for PumpCheck™ 834
Wear Metal Elements - condition
- RDE Fine Wear Metals-18 elements
- RFS Course Wear Metals-11 elements
Oil Properties & Condition
- Oil Condition ; oxidation, nitration
- Viscosity @ 40 °c
- TAN (Total Acid Number)
Contamination Condition
- Oil Contamination ; dirt & dust
- %Moisture & Water
- Wrong oil contamination*
- Gravimetric Analysis ( Insoluble Contamination Analysis)
|
- Report with interpretation
|
|
|
Highlight FocusLab's unique testing
in PumpCheck™ 834
|
|
Product Data & Service Sheet of PumpCheck TM 834 |
|
* Wrong oil contamination can be detected in case BASELINE data will be available
Note: The above recommended test package will be guideline, the suitable test package may be vary depend upon right application, environment severity, critical factor, machine age, and so on. |
Test Description
Oil Sample Quantity: 100 ml.
Oil Sampling Location/Point
- Follow OEMs recommended sampling location / point
- In the absence of OEMs guidelines , recommended below for general guidance for sampling point /location
Possible location/point will be
Pump
- Through install sampling valve as below picture
|
|
|
Vacuum Pump
- If rotary screw -vacuum pump ,prefered sampling at Filter Housing (upstream of filter)
By installing valve or minimess valve
|
Sampling Tools & Devices
Sampling Techniques
Sampling Frequency
- Initially , follow OEMs recommended sample interval for your equipment
- In the absence of OEMs guidelines , recommended below for general guidance in establishing sample interval.
Recommended Sampling Frequency (Sampling Interval)
Industry - Application |
Normal Use |
Intermittent Use |
Pump, Vacuum Pump,
Fan, Blower,
Motor (gear and bearing lubrication) |
500-700 hours
or one month
and just prior to oil drain |
Quarterly
and just prior to oil drain |
Reports
LubeCheck™ Oil Analysis Report provide :-
- Display an easy-to-read and understand.
- Information for wear condition ,lubricant condition and contamination.
- Interpretation and recommendation of the result . Option for Bilingual.
- Color coded display of overall condition for present sample and history condition of previous sample.
|
|
- Color coded problem highlights.
- Provide new oil or reference oil for comparing result and as baseline.
- Publish Alarm Limit range of the equipment and oil.
- Comprehensive trending graph of most parameters.
- LubeCheck™ Oil Analysis offers reporting options via internet, email and fax.
|
|
|
Turnaround Time Service
The report is typical available within 7-10 working days of sample receipt at FocusLab's labortory. Examples of report
Remarks: Oil samples (after completion of testing) will be retained in our laboratory for approx 60 days ,just in case of in-depth testing and/or any future purpose. |
| |
|